Opened 11 years ago

Closed 11 years ago

#347 closed defect (fixed)

another IA-32 bignum bug

Reported by: rme Owned by: rme
Priority: major Milestone: IA-32 port
Component: Runtime (threads, GC) Version: trunk
Keywords: bignum Cc:

Description

? (isqrt (expt 10 100))
> Error: DIVISION-BY-ZERO detected
> While executing: CCL::%FLOOR-99, in process listener(1).

Change History (2)

comment:1 Changed 11 years ago by rme

  • Status changed from new to assigned

Note to myself:

(BIGNUM-TRUNCATE-GUESS-2 150675752667331832761171844316690704678961498112 4 21175823681357508476708061184 2)

Returns a value one too large.

comment:2 Changed 11 years ago by rme

  • Resolution set to fixed
  • Status changed from assigned to closed

Should work in r11080.